wattbench
Inverter Fault Library

GoodWe Error Codes

GoodWe inverter error codes for grid, isolation, temperature and internal faults, with clear guidance on self-recovery versus service.

Sources listedReviewed August 2026Source: GoodWe docs & field referencesOur methodology

20 of 20 codes

About this fault librarySources · scope

A reference compiled by Wattbench from GoodWe documentation and field sources. GoodWe shows faults as a numbered error code and/or a named fault depending on the model. On an LCD unit, short-press the front button and scroll to “Error”/“Fault”; on ET/EH/EHB hybrid units, check Alarms in the SolarGo app or the SEMS portal. Where a fault has both a number and a name, we list them together, and both are searchable. Safety note: earth, insulation and PV over-voltage faults need a licensed worker. An owner should record the alarm and keep clear of isolators, wiring and connectors while the responsible installer follows the exact product procedure.

Key takeaways
  • 20 GoodWe fault and alarm codes, documented for the trade.
  • Compiled from published documentation and field references; Wattbench is independent and not affiliated with GoodWe.
  • Codes involving DC/AC isolation, wiring or opening the unit are licensed electrical work. Isolate safely and follow AS/NZS procedure.

Resolution text is manufacturer/service context, not permission for an owner to perform electrical work. Stop at visible observations unless the exact product instructions identify an owner control. Isolation, configuration, testing, opening equipment and wiring are for an appropriately licensed worker and, where required, an SAA-accredited person. Where a card says Product fit is unknown, treat it as brand-level guidance and confirm the exact model, role, regional variant, firmware and current manual before acting.

  • 1

    SPI failure

    An internal communication (SPI bus) failure inside the inverter.

    Product fit · Confirmed · ETC Series

    Show field steps for 1: SPI failure

    Product fit

    • ETC Series · Hybrid inverter

      Confirmed · Manual V1.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Record the exact code, inverter model and time. Do not operate isolators or open the inverter; contact your installer or GoodWe if the code remains.

    Installer remedy

    Follow the controlled shutdown and restart sequence for the exact model. If the fault returns, preserve the code and escalate to GoodWe after-sales rather than repeatedly resetting it.

    Remedy sourceETC manual V1.1

    Manufacturer / escalation handoff
  • 2

    EEPROM R/W failure

    A read/write failure on the inverter's memory chip.

    Product fit · Confirmed · ETC Series

    Show field steps for 2: EEPROM R/W failure

    Product fit

    • ETC Series · Hybrid inverter

      Confirmed · Manual V1.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Record the exact code, inverter model and time. Do not operate isolators or open the inverter; contact your installer or GoodWe if the code remains.

    Installer remedy

    Follow the controlled shutdown and restart sequence for the exact model. If the fault returns, preserve the code and escalate to GoodWe after-sales rather than repeatedly resetting it.

    Remedy sourceETC manual V1.1

    Manufacturer / escalation handoff
  • 3 · Fac Failure

    Grid frequency fault

    The grid frequency is outside the inverter's permissible range.

    Product fit · Confirmed · ET Series / ET Plus Series

    Show field steps for 3 · Fac Failure: Grid frequency fault

    Product fit

    • ET Series / ET Plus Series · Three-phase hybrid inverter

      Confirmed · Manual V1.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Note when the alarm occurs and whether the property supply appears normal. It should clear when grid frequency returns to range; contact your installer if it persists or repeats.

    Installer remedy

    Check the displayed and measured grid frequency against the approved operating settings. Preserve the configured country/protection profile and escalate persistent supply abnormalities through the authorised network process.

    Remedy sourceGoodWe FAQET manual

    Manufacturer / escalation handoff
  • 7 · 25

    Relay check failure

    The inverter's grid relay failed its self-check.

    Product fit · Confirmed · ETC Series

    Show field steps for 7 · 25: Relay check failure

    Product fit

    • ETC Series · Hybrid inverter

      Confirmed · Manual V1.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Record the exact code, inverter model and time. Do not operate isolators or open the inverter; contact your installer or GoodWe if the code remains.

    Installer remedy

    Check the AC neutral-to-earth condition under the model-specific procedure, then perform one controlled restart. A recurring relay check failure requires GoodWe service assessment.

    Remedy sourceETC manual V1.1

    Manufacturer / escalation handoff
  • 12

    LCD communication failure

    A communication error between the LCD/display and the master DSP.

    Product fit · Confirmed · ETC Series

    Show field steps for 12: LCD communication failure

    Product fit

    • ETC Series · Hybrid inverter

      Confirmed · Manual V1.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Record the exact code, inverter model and time. Do not operate isolators or open the inverter; contact your installer or GoodWe if the code remains.

    Installer remedy

    Follow the controlled shutdown and restart sequence for the exact model. If the fault returns, preserve the code and escalate to GoodWe after-sales rather than repeatedly resetting it.

    Remedy sourceETC manual V1.1

    Manufacturer / escalation handoff
  • 13

    DC injection high

    The DC component of the AC output current exceeds the inverter's limit.

    Product fit · Confirmed · ETC Series

    Show field steps for 13: DC injection high

    Product fit

    • ETC Series · Hybrid inverter

      Confirmed · Manual V1.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Record the exact code, inverter model and time. Do not operate isolators or open the inverter; contact your installer or GoodWe if the code remains.

    Installer remedy

    Perform one controlled restart under the exact product procedure. If the DC-injection fault returns, stop resetting and escalate immediately to GoodWe after-sales.

    Remedy sourceETC manual V1.1

    Manufacturer / escalation handoff
  • 14 · Isolation Fail

    Isolation failure

    Insulation resistance between the PV array and ground is too low, most common in rain or high humidity.

    Product fit · Confirmed · ET Series / ET Plus Series

    Show field steps for 14 · Isolation Fail: Isolation failure

    Product fit

    • ET Series / ET Plus Series · Three-phase hybrid inverter

      Confirmed · Manual V1.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Record the code, time and weather conditions. Do not reset the inverter, touch PV connectors or operate isolators; arrange a licensed inspection if it persists or returns.

    Installer remedy

    Test the PV insulation resistance to earth using the exact model limits and safe-isolation procedure. Inspect the affected string wiring, connectors, earthing and moisture exposure before returning the system to service.

    Remedy sourceGoodWe FAQET manual

    Manufacturer / escalation handoff
  • 15 · Vac Failure

    Grid voltage fault

    The grid voltage is outside the acceptable range for the inverter.

    Product fit · Confirmed · ET Series / ET Plus Series

    Show field steps for 15 · Vac Failure: Grid voltage fault

    Product fit

    • ET Series / ET Plus Series · Three-phase hybrid inverter

      Confirmed · Manual V1.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Note when the alarm occurs and whether other equipment has lost supply. The inverter should reconnect when grid voltage returns to range; contact your installer if it persists or repeats.

    Installer remedy

    Measure the inverter AC supply, verify wiring and the approved country/protection profile, and retain the settings as found. Escalate a confirmed supply-voltage issue through the authorised network process.

    Remedy sourceGoodWe FAQET manual

    Manufacturer / escalation handoff
  • 16

    External fan failure

    The external cooling fan has faulted.

    Product fit · Confirmed · ET G2 6–15 kW

    Show field steps for 16: External fan failure

    Product fit

    • ET G2 6–15 kW · Three-phase hybrid inverter

      Confirmed · Manual V2.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    From a safe position, check that the inverter's external airflow is not visibly obstructed. Do not touch the fan or open the unit; contact your installer if the alarm remains.

    Installer remedy

    Inspect the external fan and ventilation path under the product maintenance procedure. Replace a failed fan through the authorised service process.

    Remedy sourceET G2 manual V2.1

    Manufacturer / escalation handoff
  • 17 · PV Over Voltage

    PV over-voltage

    The PV array voltage exceeds the inverter's maximum input.

    Product fit · Confirmed · ET Series / ET Plus Series

    Show field steps for 17 · PV Over Voltage: PV over-voltage

    Product fit

    • ET Series / ET Plus Series · Three-phase hybrid inverter

      Confirmed · Manual V1.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Leave the inverter and PV wiring alone, record the code and contact your installer promptly. Do not reset the inverter or operate isolators to test whether it clears.

    Installer remedy

    Measure each string's open-circuit voltage under the approved procedure and compare it with the exact inverter input limit and temperature-corrected design. Correct the string design before reconnection.

    Remedy sourceGoodWe FAQET manual

    Manufacturer / escalation handoff
  • 19 · Over Temperature

    Over temperature

    The inverter's operating temperature has exceeded its safe limit.

    Product fit · Confirmed · ET G2 6–15 kW

    Show field steps for 19 · Over Temperature: Over temperature

    Product fit

    • ET G2 6–15 kW · Three-phase hybrid inverter

      Confirmed · Manual V2.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    From a safe position, keep the area around the inverter clear and note whether it is in direct sun or unusually hot. Do not open the unit; contact your installer if it does not recover after cooling.

    Installer remedy

    Check the installation ventilation, ambient conditions and fan operation against the model manual. Rectify the cooling condition or arrange service if the environment is normal and the fault persists.

    Remedy sourceET G2 manual V2.1

    Manufacturer / escalation handoff
  • 20

    Internal fan fault

    An internal cooling-fan fault (IFAN).

    Product fit · Confirmed · ET G2 6–15 kW

    Show field steps for 20: Internal fan fault

    Product fit

    • ET G2 6–15 kW · Three-phase hybrid inverter

      Confirmed · Manual V2.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Record the exact code, inverter model and time. Do not operate isolators or open the inverter; contact your installer or GoodWe if the code remains.

    Installer remedy

    Confirm ventilation and ambient conditions, then inspect fan operation under the authorised service procedure. An internal fan fault that remains requires service; do not leave the enclosure open in operation.

    Remedy sourceET G2 manual V2.1

    Manufacturer / escalation handoff
  • 21

    DC bus high

    The internal DC bus voltage is too high.

    Product fit · Confirmed · ETC Series

    Show field steps for 21: DC bus high

    Product fit

    • ETC Series · Hybrid inverter

      Confirmed · Manual V1.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Record the exact code, inverter model and time. Do not operate isolators or open the inverter; contact your installer or GoodWe if the code remains.

    Installer remedy

    Follow the controlled shutdown and restart sequence for the exact model. If the fault returns, preserve the code and escalate to GoodWe after-sales rather than repeatedly resetting it.

    Remedy sourceETC manual V1.1

    Manufacturer / escalation handoff
  • 22 · Ground I Fail

    Ground (residual) current failure

    Residual-current (earth-leakage) protection has tripped. Current is leaking to ground.

    Product fit · Confirmed · ETC Series

    Show field steps for 22 · Ground I Fail: Ground (residual) current failure

    Product fit

    • ETC Series · Hybrid inverter

      Confirmed · Manual V1.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Record the code, time and weather conditions. Do not reset the inverter or touch system wiring; arrange a licensed inspection if the alarm persists or returns.

    Installer remedy

    Test the PV strings and AC earthing/neutral conditions under the exact product procedure. Locate damaged insulation, moisture ingress or an abnormal earth path before returning the system to service.

    Remedy sourceGoodWe FAQETC manual V1.1

    Manufacturer / escalation handoff
  • 23 · Utility Loss

    Utility (grid) loss

    Loss of connection between the inverter and the utility grid, an outage or a disconnection.

    Product fit · Confirmed · ET Series / ET Plus Series

    Show field steps for 23 · Utility Loss: Utility (grid) loss

    Product fit

    • ET Series / ET Plus Series · Three-phase hybrid inverter

      Confirmed · Manual V1.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Check whether the property and neighbourhood have grid supply, then record the code and time. Do not operate solar isolators; contact your installer if normal grid supply is present but the alarm remains.

    Installer remedy

    Verify AC supply at the inverter, protective-device state and AC wiring under the approved procedure. If supply and wiring are sound, follow the model troubleshooting path and escalate to GoodWe.

    Remedy sourceGoodWe FAQET manual

    Manufacturer / escalation handoff
  • 24 · 31

    AC HCT (current sensor) failure

    The AC current sensor (HCT) has failed.

    Product fit · Confirmed · ET G2 6–15 kW

    Show field steps for 24 · 31: AC HCT (current sensor) failure

    Product fit

    • ET G2 6–15 kW · Three-phase hybrid inverter

      Confirmed · Manual V2.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Record the exact code, inverter model and time. Do not operate isolators or open the inverter; contact your installer or GoodWe if the code remains.

    Installer remedy

    Perform one controlled shutdown and restart under the exact model procedure. If the AC current-sensor fault persists, arrange GoodWe service rather than attempting an internal repair.

    Remedy sourceET G2 manual V2.1

    Manufacturer / escalation handoff
  • 26 · 32

    GFCI failure

    A failure in the leakage-current (GFCI) detection circuit.

    Product fit · Confirmed · ET G2 6–15 kW

    Show field steps for 26 · 32: GFCI failure

    Product fit

    • ET G2 6–15 kW · Three-phase hybrid inverter

      Confirmed · Manual V2.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Record the exact code, inverter model and time. Do not operate isolators or open the inverter; contact your installer or GoodWe if the code remains.

    Installer remedy

    Perform one controlled shutdown and restart under the exact model procedure. A persistent GFCI sensing fault requires prompt service because the leakage-current detection circuit cannot be relied upon.

    Remedy sourceET G2 manual V2.1

    Manufacturer / escalation handoff
  • 30

    Reference 1.5 V failure

    The internal 1.5 V reference voltage is out of range.

    Product fit · Confirmed · ETC Series

    Show field steps for 30: Reference 1.5 V failure

    Product fit

    • ETC Series · Hybrid inverter

      Confirmed · Manual V1.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Record the exact code, inverter model and time. Do not operate isolators or open the inverter; contact your installer or GoodWe if the code remains.

    Installer remedy

    Follow the controlled shutdown and restart sequence for the exact model. If the fault returns, preserve the code and escalate to GoodWe after-sales rather than repeatedly resetting it.

    Remedy sourceETC manual V1.1

    Manufacturer / escalation handoff
  • PE Loss

    Protective earth (PE) loss

    A missing or faulty protective-earth connection, possibly loose wiring, corrosion, or grounding-system damage.

    Product fit · Confirmed · ET Series / ET Plus Series

    Show field steps for PE Loss: Protective earth (PE) loss

    Product fit

    • ET Series / ET Plus Series · Three-phase hybrid inverter

      Confirmed · Manual V1.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Do not reset the inverter or touch electrical equipment. Record the code and arrange a licensed electrician or your installer to attend.

    Installer remedy

    Verify the protective-earth connection and continuity under the approved safe-isolation procedure. Rectify the earthing fault before the inverter is returned to service.

    Remedy sourceGoodWe FAQET manual

    Manufacturer / escalation handoff
  • Device Failure

    Internal device failure

    A general internal device failure (shown for faults outside the listed codes).

    Product fit · Confirmed · ET G2 6–15 kW

    Show field steps for Device Failure: Internal device failure

    Product fit

    • ET G2 6–15 kW · Three-phase hybrid inverter

      Confirmed · Manual V2.1 · AU/region not confirmed · Firmware not documented

    Safe checks now

    Record the exact code, inverter model and time. Do not operate isolators or open the inverter; contact your installer or GoodWe if the code remains.

    Installer remedy

    Follow the controlled shutdown and restart sequence for the exact model. If the fault returns, preserve the code and escalate to GoodWe after-sales rather than repeatedly resetting it.

    Remedy sourceET G2 manual V2.1

    Manufacturer / escalation handoff

Sources

Continue this work

Did this help you move the job forward?

Tell us what is missing
Good to know

Frequently asked

Where do these GoodWe fault codes come from?
Compiled from publicly available GoodWe inverter and battery documentation and field references, then rewritten for the trade. Wattbench is independent and not affiliated with GoodWe.
Which of these can I clear on site?
Some clear on their own once grid or environmental conditions return to normal. Anything involving DC isolation, AC switching, wiring or opening the unit is licensed electrical work. Isolate safely, follow AS/NZS 5033 and AS/NZS 3000 procedure and use appropriate PPE before touching a live system.
The exact code isn't listed. Why not?
Firmware and model variants differ, and manufacturers revise their code tables. We document the most common ones; for a variant that isn't here, check the unit's current manual or the manufacturer's service portal.
How current is this reference?
This reference was last reviewed on 2 August 2026. We revise entries when the underlying manufacturer documentation changes.