Sigenergy SigenStor Fault Codes
Common SigenStor alarms (the 1000-series inverter codes) explained, with what each points to and what to check.
13 of 13 codes
About this fault librarySources · scope
Sigenergy's SigenStor combines PV, battery and energy-control functions, so its alarm list spans the full system. Codes appear in mySigen and SigenCloud as a four-digit alarm with a sub-ID that identifies the affected string, phase or communication link. This library includes only the 1000-series operational alarms verified in Sigenergy Alarm List v05. Safety note: owners should record the alarm and stop at safe visual observations or ordinary app support. DC/AC isolation, electrical measurements, settings, wiring and opening equipment are licensed-worker tasks completed under the exact product and site procedure.
- 13 Sigenergy (SigenStor) fault and alarm codes, documented for the trade.
- Compiled from published documentation and field references; Wattbench is independent and not affiliated with Sigenergy (SigenStor).
- Codes involving DC/AC isolation, wiring or opening the unit are licensed electrical work. Isolate safely and follow AS/NZS procedure.
Resolution text is manufacturer/service context, not permission for an owner to perform electrical work. Stop at visible observations unless the exact product instructions identify an owner control. Isolation, configuration, testing, opening equipment and wiring are for an appropriately licensed worker and, where required, an SAA-accredited person. Where a card says Product fit is unknown, treat it as brand-level guidance and confirm the exact model, role, regional variant, firmware and current manual before acting.
- 1002
Low insulation resistance (ISO fault)
The inverter has measured low insulation resistance on the PV (DC) side, meaning the system is detecting a possible leakage path to earth. Common triggers are moisture ingress in a connector or cable, a damaged DC cable, or a string partially shorting to the protective earth (PE). It often appears in the early morning when humidity is highest and may self-clear as things dry out.
Product fit · Family-level · SigenStor
Show field stepsHide field steps for 1002: Low insulation resistance (ISO fault)
Product fit
SigenStor · Integrated energy-storage system
Family-level · Manual Version 05 · AU/region not confirmed · Firmware not documented
Safe checks now
Record the alarm, sub-ID, time and weather conditions. Keep clear of PV wiring and do not operate isolators; contact your installer if the low-insulation alarm persists or repeats.
Installer remedy
Under the approved safe-isolation procedure, check the identified DC cable for short circuit, damage and positive- or negative-to-earth faults. Verify the ISO threshold against local requirements and submit app feedback if the alarm remains.
Remedy sourceAlarm List v05
Manufacturer / escalation handoff
- 1003
Inverter over-temperature
The inverter has exceeded its safe internal operating temperature and has throttled or shut down to protect itself. Usual causes are high ambient temperature, the unit sitting in direct sun, or restricted airflow/poor ventilation around the tower.
Product fit · Family-level · SigenStor
Show field stepsHide field steps for 1003: Inverter over-temperature
Product fit
SigenStor · Integrated energy-storage system
Family-level · Manual Version 05 · AU/region not confirmed · Firmware not documented
Safe checks now
From a safe position, check that external ventilation is not visibly obstructed and note whether the unit is in direct sun. Allow it to cool; do not open the enclosure and contact your installer if it persists.
Installer remedy
Check ventilation and direct-sun exposure against the installation requirements. The unit should restart after temperature returns to normal; submit app feedback if the alarm remains under compliant conditions.
Remedy sourceAlarm List v05
Manufacturer / escalation handoff
- 1006
String input overvoltage (PV)
The DC voltage from a PV string (the sub-ID identifies which string: e.g. ID1 = String 1) is above the inverter's maximum allowed input voltage. This almost always means too many panels were wired in series for that string, and the problem shows up worst on cold, bright mornings when panel voltage peaks.
Product fit · Family-level · SigenStor
Show field stepsHide field steps for 1006: String input overvoltage (PV)
Product fit
SigenStor · Integrated energy-storage system
Family-level · Manual Version 05 · AU/region not confirmed · Firmware not documented
Safe checks now
Leave the SigenStor and PV wiring alone, record the alarm and string sub-ID, and contact your installer promptly. Do not reset the system or operate isolators to test whether it clears.
Installer remedy
Under the approved safe-isolation procedure, measure the identified string voltage and compare it with the exact product limit and string design. Reduce the series module count if required before reconnection and submit app feedback if the alarm remains.
Remedy sourceAlarm List v05
Manufacturer / escalation handoff
- 1009
AFCI fault (DC arc detected)
The arc-fault circuit interrupter has detected what looks like an electrical arc on a PV string (the sub-ID flags which string). This is a genuine fire-safety feature. Arcs are usually caused by a damaged DC cable, a loose or corroded connector, or a poor contact at a string terminal.
Product fit · Family-level · SigenStor
Show field stepsHide field steps for 1009: AFCI fault (DC arc detected)
Product fit
SigenStor · Integrated energy-storage system
Family-level · Manual Version 05 · AU/region not confirmed · Firmware not documented
Safe checks now
Treat the arc alarm as urgent: record the string sub-ID, keep clear of the equipment and contact your installer. Do not clear the alarm, operate isolators or touch PV connectors or wiring.
Installer remedy
Disconnect the PV DC supply under the approved safe-isolation procedure, then inspect the identified string's cables, connectors and terminations for damage, looseness or burning. Rectify the cause before clearing the alarm in the app; submit support feedback if it remains.
Remedy sourceAlarm List v05
Manufacturer / escalation handoff
- 1010
Grid power outage / grid power failure lock
The inverter has detected that the grid has gone away, either an actual blackout or the AC isolator/main switch being turned off (ID1). A persistent or repeated loss can put the system into a grid-failure lock state (ID2). With backup configured, the system transfers to battery/backup; otherwise it stops exporting and waits.
Product fit · Family-level · SigenStor
Show field stepsHide field steps for 1010: Grid power outage / grid power failure lock
Product fit
SigenStor · Integrated energy-storage system
Family-level · Manual Version 05 · AU/region not confirmed · Firmware not documented
Safe checks now
Check whether the property and neighbourhood have grid supply, then record the alarm and sub-ID. The system should reconnect automatically; contact your installer if normal supply is present but the alarm remains locked.
Installer remedy
Verify reliable grid supply, AC switch and circuit-breaker state, and whether off-grid operation is correctly enabled. Clear the ID2 lock in the app only after the site condition is confirmed safe; submit feedback if it remains.
Remedy sourceAlarm List v05
Manufacturer / escalation handoff
- 1011
Grid overvoltage (Level I / II / III)
The grid voltage at your connection point has risen above the allowed protection threshold, so the inverter disconnects to protect itself and comply with grid rules. Level I is mildest, Level III most severe. This is one of the most common alarms in Australia, especially around midday in areas with lots of rooftop solar pushing voltage up.
Product fit · Family-level · SigenStor
Show field stepsHide field steps for 1011: Grid overvoltage (Level I / II / III)
Product fit
SigenStor · Integrated energy-storage system
Family-level · Manual Version 05 · AU/region not confirmed · Firmware not documented
Safe checks now
Record the alarm, sub-ID and time, then wait for automatic recovery when the grid returns to range. Contact your installer if the alarm persists or repeats; do not change protection settings.
Installer remedy
Measure the actual grid voltage and compare it with the approved protection settings. Preserve the commissioned profile, contact the grid operator if supply is abnormal and change protection only with operator consent; submit app feedback if the alarm persists.
Remedy sourceAlarm List v05
Manufacturer / escalation handoff
- 1012
Grid undervoltage (Level I / II / III)
The grid voltage has dropped below the protection threshold, so the inverter disconnects until it recovers. It usually reflects a weak or sagging grid supply rather than an inverter fault, and is more common on long rural feeders or during high-demand periods.
Product fit · Family-level · SigenStor
Show field stepsHide field steps for 1012: Grid undervoltage (Level I / II / III)
Product fit
SigenStor · Integrated energy-storage system
Family-level · Manual Version 05 · AU/region not confirmed · Firmware not documented
Safe checks now
Record the alarm, sub-ID and time, then wait for automatic recovery when the grid returns to range. Contact your installer if the alarm persists or repeats; do not change protection settings.
Installer remedy
Measure the actual grid voltage and compare it with the approved protection settings. Preserve the commissioned profile, contact the grid operator if supply is abnormal and change protection only with operator consent; submit app feedback if the alarm persists.
Remedy sourceAlarm List v05
Manufacturer / escalation handoff
- 1013
Grid overfrequency (Level I / II / III)
The grid frequency has risen above the allowed threshold and the inverter has disconnected per grid protection rules. This is a grid-side condition, not an internal fault, and usually clears within seconds.
Product fit · Family-level · SigenStor
Show field stepsHide field steps for 1013: Grid overfrequency (Level I / II / III)
Product fit
SigenStor · Integrated energy-storage system
Family-level · Manual Version 05 · AU/region not confirmed · Firmware not documented
Safe checks now
Record the alarm, sub-ID and time, then wait for automatic recovery when the grid returns to range. Contact your installer if the alarm persists or repeats; do not change protection settings.
Installer remedy
Measure the actual grid frequency and compare it with the approved protection settings. Preserve the commissioned profile, contact the grid operator if supply is abnormal and submit app feedback if the alarm persists.
Remedy sourceAlarm List v05
Manufacturer / escalation handoff
- 1014
Grid underfrequency (Level I / II / III)
The grid frequency has fallen below the allowed threshold and the inverter has disconnected to comply with grid protection requirements. Like overfrequency, it is a grid-side event that normally clears within seconds.
Product fit · Family-level · SigenStor
Show field stepsHide field steps for 1014: Grid underfrequency (Level I / II / III)
Product fit
SigenStor · Integrated energy-storage system
Family-level · Manual Version 05 · AU/region not confirmed · Firmware not documented
Safe checks now
Record the alarm, sub-ID and time, then wait for automatic recovery when the grid returns to range. Contact your installer if the alarm persists or repeats; do not change protection settings.
Installer remedy
Measure the actual grid frequency and compare it with the approved protection settings. Preserve the commissioned profile, contact the grid operator if supply is abnormal and submit app feedback if the alarm persists.
Remedy sourceAlarm List v05
Manufacturer / escalation handoff
- 1017
Leak current out of limit
The inverter has measured residual/leakage current above its safety threshold. It is often transient, caused by damp conditions or a momentary disturbance, and the system typically recovers once the environment settles.
Product fit · Family-level · SigenStor
Show field stepsHide field steps for 1017: Leak current out of limit
Product fit
SigenStor · Integrated energy-storage system
Family-level · Manual Version 05 · AU/region not confirmed · Firmware not documented
Safe checks now
Record the alarm, sub-ID, time and conditions, then allow the system's automatic recovery. Do not reset or open the unit; contact your installer if the alarm is frequent or prolonged.
Installer remedy
Preserve the alarm history and conditions and allow the documented automatic recovery. For a frequent or prolonged leakage-current alarm, submit support feedback and follow only the resulting manufacturer-directed diagnostic path.
Remedy sourceAlarm List v05
Manufacturer / escalation handoff
- 1018
Communication fault (4G / CAN / meter / gateway)
A communication link inside the system has dropped: for example the 4G/monitoring module (ID1), the battery CAN bus (ID2), the energy meter (ID3), or the gateway (ID4). The sub-ID identifies which link. Monitoring or energy-management features may stop working while it is active even if power flow continues.
Product fit · Family-level · SigenStor
Show field stepsHide field steps for 1018: Communication fault (4G / CAN / meter / gateway)
Product fit
SigenStor · Integrated energy-storage system
Family-level · Manual Version 05 · AU/region not confirmed · Firmware not documented
Safe checks now
Record the alarm and sub-ID shown in mySigen, because it identifies the affected 4G, CAN, meter or gateway link. Do not open the enclosure; use app support if the alarm persists.
Installer remedy
Match the sub-ID to the affected link: check 4G service and dongle status, use the documented controlled restart for CAN, or inspect the specified meter or gateway communication port. Submit app feedback if communication does not recover.
Remedy sourceAlarm List v05
Manufacturer / escalation handoff
- 1022
EPO / emergency stop activated
The emergency power-off (EPO) input has been triggered, typically because someone pressed the emergency-stop button (or, on some installs, a shutdown command in the mySigen app). The system stays shut down for safety until the EPO is released.
Product fit · Family-level · SigenStor
Show field stepsHide field steps for 1022: EPO / emergency stop activated
Product fit
SigenStor · Integrated energy-storage system
Family-level · Manual Version 05 · AU/region not confirmed · Firmware not documented
Safe checks now
If emergency stop was activated for a hazard, leave the system stopped and keep people clear. After a competent person confirms the site is safe, follow the exact installed emergency-stop control instructions or contact your installer.
Installer remedy
Establish why EPO was activated and confirm the site is safe before restoration. Reset only through the documented installed emergency-stop or app control, then submit app feedback if the alarm does not clear.
Remedy sourceAlarm List v05
Manufacturer / escalation handoff
- 1023
Neutral disconnected / abnormal AC wiring
The inverter has detected a problem with the AC wiring, most commonly a neutral conductor that is disconnected or has worked loose inside the inverter (ID1), or otherwise abnormal AC wiring (ID2). A poor neutral connection can be a safety hazard.
Product fit · Family-level · SigenStor
Show field stepsHide field steps for 1023: Neutral disconnected / abnormal AC wiring
Product fit
SigenStor · Integrated energy-storage system
Family-level · Manual Version 05 · AU/region not confirmed · Firmware not documented
Safe checks now
Do not reset the system, operate electrical switches or touch AC wiring. Record the alarm and sub-ID and arrange attendance by your installer or a licensed electrician.
Installer remedy
Place the system in standby or shutdown through the documented app procedure, isolate the grid supply and inspect the neutral connection under safe isolation. Rectify the loose or disconnected neutral, then restore and start the system through the manufacturer sequence.
Remedy sourceAlarm List v05
Manufacturer / escalation handoff
Sources
Continue this work
Did this help you move the job forward?
Frequently asked
- Where do these Sigenergy fault codes come from?
- Compiled from publicly available Sigenergy inverter and battery documentation and field references, then rewritten for the trade. Wattbench is independent and not affiliated with Sigenergy.
- Which of these can I clear on site?
- Some clear on their own once grid or environmental conditions return to normal. Anything involving DC isolation, AC switching, wiring or opening the unit is licensed electrical work. Isolate safely, follow AS/NZS 5033 and AS/NZS 3000 procedure and use appropriate PPE before touching a live system.
- The exact code isn't listed. Why not?
- Firmware and model variants differ, and manufacturers revise their code tables. We document the most common ones; for a variant that isn't here, check the unit's current manual or the manufacturer's service portal.
- How current is this reference?
- This reference was last reviewed on 2 August 2026. We revise entries when the underlying manufacturer documentation changes.
Other fault libraries
Tesla Powerwall Alert Codes
What Tesla Powerwall's app alerts mean, from Breaker Open to Storm Watch, and what to do about them.
11 codesInverter Fault LibraryDeye Inverter Fault Codes
Deye SG04LP3-AU fault-table guidance, with deployed-firmware F08/F35 residues labelled and left without unsupported remedies.
23 codesInverter Fault LibraryFoxESS Inverter Error Codes
FoxESS hybrid and R-series alarms with separate owner-safe checks and source-linked installer remedies.
48 codes