Compliance update

Victorian networks now require CSIP-AUS 1.2 inverters

From 1 November 2026, Victorian networks require inverters, and batteries and V2G chargers under network control, to be listed as CSIP-AUS 1.2 compliant.

In forceIn force from 1 November 2026
Sources listedReviewed November 2026Our methodology

Update status

Authority
In force
Timing
In force from 1 November 2026
Jurisdiction
Victoria
Evidence
Source checked
Reviewed
22 Nov 2026
Next review
22 Feb 2027

In force from 1 November 2026, as stated by CitiPower & Powercor, United Energy and AusNet on their own pages. No regulator page read so far states the change; this briefing rests on the networks.

Field brief

What changed
Victorian distribution networks moved to CSIP-AUS 1.2 (SA TS 5573:2025) on 1 November 2026. An inverter for a new installation has to be listed as CSIP-AUS 1.2 compliant, not just CSIP-AUS compliant.
Why it matters
An inverter that is not listed can no longer be submitted through an alteration request in the CitiPower & Powercor or United Energy portals, so the problem surfaces at close-out, after the hardware is on the wall.
On the next job
Before ordering, check the model is listed as CSIP-AUS 1.2 compliant on the Clean Energy Council's list and on the network's own approved list. Include any battery or V2G charger that may be under network control. For an older model, get the manufacturer's word on the firmware path first.
Watch for
Jemena publishing the requirement on its own installer pages (they did not state it when last read), AusNet's online approved list returning from its upgrade, and any regulator or Victorian Government page stating the change.

What changed

From 1 November 2026, all solar inverters installed in Victoria must comply with CSIP-AUS 1.2 (SA TS 5573:2025), according to CitiPower & Powercor and United Energy.

Source12

Both say that from that date all Victorian electricity distribution businesses are required to comply with the updated standard.

Source12

AusNet states that from 1 November 2026, inverters for new installations must be CSIP-AUS 1.2 compliant.

Source3

What to check before the job

The model has to be listed as CSIP-AUS 1.2 compliant on both the Clean Energy Council's list and the network's own approved inverter list.

Source123

Other devices that may be under network control for emergency backstop or flexible exports, including batteries and vehicle-to-grid chargers, also need to be CSIP-AUS 1.2 compliant.

Source12

An inverter model that is not CSIP-AUS 1.2 compliant can no longer be submitted through an alteration request in the CitiPower & Powercor or United Energy portals.

Source12

Many existing models may reach compliance through a firmware update; the networks refer model-specific questions to the manufacturer.

Source12

Official source ledger

  1. New CSIP-AUS 1.2 Requirements for Solar and DER Installations from 1 November 2026

    CitiPower & Powercor · web page

    Source checked 22 Nov 2026 · Published 2 Nov 2026

  2. AusNet approved inverter list

    AusNet · web page

    Source checked 22 Nov 2026

Did this help you move the job forward?

Tell us what is missing

Ask Watt

Ask the bench a question.

Answers on fault codes, calculators, AS/NZS scope and current field updates, every one drawn from Wattbench with the source attached. It won’t guess a code or a standard.